Running room

From WikiMD's Wellness Encyclopedia

Implant platforms are circular in nature and generally exhibit a diameter of 3-6 mm, depending on the tooth to be restored. The mesial-distal dimension to be filled by the implant-supported crown (upper red line) will generally be considerably greater than the diameter of the implant platform (bottom center) and the difference between these two dimensions (orange arrows) is gained in the apico-coronal distance between the implant platform and the contact points of the two teeth adjacent to the edentulous space (red arrow) being restored by the implant. It is desirable that a greater proportion of this horizontal change in crown width be achieved in the vertical distance between the implant platform and the gingival margin (gumline) so as to achieve an emergence profile as similar to natural as possible. The vertical dimension between the implant platform and the gingival margin is termed running room.

In implant dentistry, running room refers to the apico-coronal distance between the platform of a dental implant and the gingival margin. It is a critical factor in restorative implant dentistry because it is effectively the "vertical distance [available subgingivaly] to make a transition from the smaller diameter prosthetic platform of an implant to the larger cross-sectional cervical shape of the tooth being restored."[1] The term was coined by Jonathan Zamzok, a Manhattan prosthodontist, in the late 1990s.[2]

Rationale[edit | edit source]

Adequate running room is necessary to allow the implant-supported crown to exhibit a tooth-shaped contour despite the smaller diameter and circular nature of implant platforms.[3] For example, the mean mesial-distal dimension of a maxillary central incisor at the points at which it contacts the adjacent teeth is 8.6 mm, and the mean mesial-distal dimension of the same tooth at the cementoenamel junction (CEJ) is 6.4 mm.[4] However, the implant diameter chosen for the maxillary central incisor is usually around 4-5 mm, but the supragingival tooth contours need to mimic those of the natural tooth is esthetic success is intended.

As the anatomical crown and root tapers towards the apex, the mesial-distal dimension decreases, and so the mean mesial-distal dimension at the marginal crest of bone, which lies approximately 2 mm apical to the CEJ, is smaller. The tooth has the apico-coronal distance from the marginal crest of bone to the contact point in order to increase from the much narrower mesial-distal dimension to the greater mesial-distal dimension, and this distance is partially subgingival (below the gum line) and partially supragingival (above the gun line). Running room refers to this subgingival apico-coronal distance.

In general, it is recommended that implants be given approximately 3mm of running room in compliance with the rule of thumb that implants should be placed as deep as necessary and as shallow as possible.[5]

When implants are placed too palatally or lingually due to aberrant anatomical landmarks, bone resorption or surgical error, it is wise to place the implant more apically to increase the available running room in order to allow for a more convex emergence profile and avoid a buccal ridge-lap of the prosthetic crown in fixed partial denture cases.[5]

References[edit | edit source]

  1. Cavallaro Jr. JS, Greenstein G: Prosthodontic complications related to non-optimal dental implant placement. In Froum, editor: Dental Implant Complications: Etiology, Prevention, and Treatment. Oxford: Wiley-Blackwell 2010. page 157
  2. Zamzok J. Nonsurgical soft tissue sculpting. Alpha Omegan 1997;90:65-69
  3. Smith RB, Tarnow DP. Classification of molar extraction sites for immediate dental implant placement: technical note. Int J Oral Maxillofac Impl 2013;28:911-916
  4. Scheid RC, Woelfel JB. Woelfel's Dental Anatomy: its relevance to dentistry, Lippincott Williams & Wilkins, 2007 ISBN 0781768608
  5. 5.0 5.1 Greenstein G, Cavallaro J. The relationship between biologic concepts and fabrication of surgical guides for dental implant placement. Compendium 2007;28(4):130-137

Contributors: Prab R. Tumpati, MD