Rubidium chloride rb-82

From WikiMD's Wellness Encyclopedia

What is Rubidium chloride rb-82?[edit | edit source]


What are the uses of this medicine?[edit | edit source]

  • Rubidium chloride rb-82 (cardiogen-82; Ruby-Fill) is a closed system used to produce rubidium Rb 82 chloride injection for intravenous administration.
  • Rubidium Rb 82 chloride injection is indicated for Positron Emission Tomography (PET) imaging of the myocardium under rest or pharmacologic stress conditions to evaluate regional myocardial perfusion in adult patients with suspected or existing coronary artery disease.


How does this medicine work?[edit | edit source]

  • Rubidium-82 chloride is a form of rubidium chloride containing a radioactive isotope of rubidium.
  • It is marketed under the brand name cardiogen-82 by Bracco diagnostics for use in Myocardial perfusion imaging.
  • It is rapidly taken up by heart muscle cells, and therefore can be used to identify regions of heart muscle that are receiving poor blood flow in a technique called PET perfusion imaging.
  • The half-life of the rubidium-82 is only 1.27 minutes; it is normally produced at the place of use by rubidium generators.


Who Should Not Use this medicine ?[edit | edit source]

This medicine cannot be used in patients:

  • whenever the incorrect eluent is used (if a solution other than additive free 0.9% Sodium Chloride Injection USP has been used to elute the generator at any time).


What drug interactions can this medicine cause?[edit | edit source]

  • Tell your healthcare provider about all the medicines you take, including prescription and over-the-counter medicines, vitamins, and herbal supplements.


Is this medicine FDA approved?[edit | edit source]

  • Initial U.S. Approval: 1989


How should this medicine be used?[edit | edit source]

Recommended dosage: CardioGen-82:

  • The recommended adult (70 kg) single dose of rubidium Rb 82 chloride injection is 1,480 MBq (40 mCi), with a range of 1,110 MBq to 2,220 MBq (30 mCi to 60 mCi).
  • Do not exceed a single dose of 2,220 MBq (60 mCi) per rest or stress component of a procedure.

Ruby-Fill:

  • The recommended weight-based dose of rubidium Rb 82 is between 10 to 30 Megabecquerels (MBq)/kg [0.27 to 0.81 millicuries (mCi)/kg].
  • Do not exceed a single dose of 2220 MBq (60 mCi) per rest or stress component of a procedure.

Administration:

  • Administer via intravenous infusion at a rate of 50 mL/minute (Model 510 and Model 1700), or at a rate of 20 mL/minute (Model 1700 only).
  • Use only additive free 0.9% Sodium Chloride Injection USP to elute the generator.
  • Use the lowest dose necessary to obtain adequate cardiac visualization. Individualize the dose depending on multiple factors, including patient weight, imaging equipment and acquisition type used to perform the procedure.
  • Start imaging acquisition 60 to 90 seconds after completion of the infusion; if a longer circulation time is anticipated, wait for 120 seconds. Image acquisition is typically 5 minutes long.
  • To obtain both rest and stress images, wait 10 minutes after completion of the rest image acquisition, then administer the pharmacologic stress agent in accordance with its prescribing information. Then, at a time interval after the administration of the pharmacologic stress agent that is in accordance with its prescribing information, infuse the second dose of rubidium Rb 82 chloride and complete the stress image acquisition.


What are the dosage forms and brand names of this medicine?[edit | edit source]

This medicine is available in fallowing doasage form:

  • As CardioGen-82 consists of strontium Sr 82 adsorbed on a hydrous stannic oxide column with an activity of 3,330 MBq to 5,550 MBq (90 millicuries to 150 millicuries) Sr 82 at calibration time.
  • Ruby-Fill consists of Sr 82 adsorbed on a hydrous stannic oxide column with an activity of 3145 to 4255 MBq (85 to 115 mCi) Sr 82 at calibration time.

This medicine is available in fallowing brand namesː

  • CardioGen-82; Ruby-Fill


What side effects can this medication cause?[edit | edit source]

The most common side effects of this medicine include:

  • Radiation Exposure


What special precautions should I follow?[edit | edit source]

  • Use only additive-free 0.9% Sodium Chloride Injection USP to elute the generator.
  • Additives present in other solutions (particularly calcium ions) expose patients to high levels of radiation by causing the release of large amounts of Sr 82 and Sr 85 into the eluate regardless of the generator’s age or prior use.
  • Immediately stop the patient infusion and discontinue use of the affected Ruby-Fill/CardioGen-82 generator if the incorrect eluent is used and evaluate the patient’s radiation absorbed dose and monitor for the effects of radiation to critical organs such as bone marrow.
  • Excess radiation exposure occurs when the Sr 82 and Sr 85 levels in rubidium Rb 82 chloride injections exceed the specified generator eluate limits. Excess radiation exposure occurs when the Sr 82 and Sr 85 levels in rubidium Rb 82 chloride injections exceed the specified generator eluate limits.
  • Pharmacologic induction of cardiovascular stress may be associated with serious adverse reactions such as myocardial infarction, arrhythmia, hypotension, bronchoconstriction, and cerebrovascular events.
  • Ensure safe handling to minimize radiation exposure to the patient and health care providers. Advise patients to void after completion of each image acquisition session and as often as possible for one hour after completion of the PET scan.
  • Advise a pregnant woman of the potential risk to a fetus.
  • Advise lactating women that exposure to Rb 82 chloride through breast milk can be minimized if breastfeeding is discontinued when Rb 82 chloride injection is administered. Advise lactating women not to resume breastfeeding for at least one hour after completion of rubidium Rb 82 infusion.


What to do in case of emergency/overdose?[edit | edit source]

  • In case of overdose, call the poison control helpline of your country. In the United States, call 1-800-222-1222.


Can this medicine be used in pregnancy?[edit | edit source]

  • There are no data available on the use of rubidium Rb 82 chloride in pregnant women.
  • If considering rubidium Rb 82 chloride injection administration to a pregnant woman, inform the patient about the potential for adverse pregnancy outcomes based on the radiation dose from rubidium Rb 82 and the gestational timing of exposure.


Can this medicine be used in children?[edit | edit source]

  • Rubidium Rb 82 chloride injection safety and effectiveness in pediatric patients have not been established.


What are the active and inactive ingredients in this medicine?[edit | edit source]

Active ingredient:

  • RUBIDIUM CHLORIDE RB-82

Inactive ingredients:

  • none

Who manufactures and distributes this medicine?[edit | edit source]

CardioGen-82 Manufactured for:

By:

  • GE Healthcare Medi-Physics, Inc.,
  • South Plainfield, NJ

Ruby-Fill Manufactured by:


What should I know about storage and disposal of this medication?[edit | edit source]

  • Store the generator at 20° to 25°C (68° to 77°F).
  • Receipt, transfer, possession, storage, disposal or use of this product is subject to the radioactive material regulations and licensing requirements of the U.S. Nuclear Regulatory Commission (NRC), Agreement States or Licensing States as appropriate. Do not dispose of the generator in regular refuse systems.


Rubidium chloride rb-82 Resources
Wikipedia



WikiMD
Navigation: Wellness - Encyclopedia - Health topics - Disease Index‏‎ - Drugs - World Directory - Gray's Anatomy - Keto diet - Recipes

Search WikiMD

Ad.Tired of being Overweight? Try W8MD's physician weight loss program.
Semaglutide (Ozempic / Wegovy and Tirzepatide (Mounjaro / Zepbound) available.
Advertise on WikiMD

WikiMD's Wellness Encyclopedia

Let Food Be Thy Medicine
Medicine Thy Food - Hippocrates

Medical Disclaimer: WikiMD is not a substitute for professional medical advice. The information on WikiMD is provided as an information resource only, may be incorrect, outdated or misleading, and is not to be used or relied on for any diagnostic or treatment purposes. Please consult your health care provider before making any healthcare decisions or for guidance about a specific medical condition. WikiMD expressly disclaims responsibility, and shall have no liability, for any damages, loss, injury, or liability whatsoever suffered as a result of your reliance on the information contained in this site. By visiting this site you agree to the foregoing terms and conditions, which may from time to time be changed or supplemented by WikiMD. If you do not agree to the foregoing terms and conditions, you should not enter or use this site. See full disclaimer.
Credits:Most images are courtesy of Wikimedia commons, and templates Wikipedia, licensed under CC BY SA or similar.

Contributors: Deepika vegiraju